Magnetron, Dauerstrichmagnetron M-104
Art.Nr.: roe-mag-0288z
Magnetron, Dauerstrichmagnetron M-104, russisch М-104
Magnetron, Dauerstrichmagnetron M-104
Construction - packaged with tow anodes which provides generation on two frequencies.
Output power adjustment range without filament voltage change-up to 100%.
Quasi-pulsed mode provides measurement of tissue temperature without microwave inducing on test probes during intervals between pulses.

Russisches Magnetron, Dauerstrichmagnetron M-104, russisch МАГНЕТРОН М-104.
Quasi-gepulster Modus, bietet die Messung der Gewebetemperatur während der Intervalle zwischen den Impulsen.
russian magnetron, type M-104, М-104 technical datas below.
Construction - packaged with tow anodes which provides generation on two frequencies.
Output power adjustment range without filament voltage change-up to 100%.
Quasi-pulsed mode provides measurement of tissue temperature without microwave inducing on test probes during intervals between pulses.
M-104, М-104
Dauerstrich- Magnetron M-104Technische Daten Magnetron M-104, М-104
|
|
| Schalthäufigkeit, GHz |
|
| Ausgangsleistung (Durchschnitt), W |
|
| Anodenspannung (Peak), kV, nicht mehr als |
|
| Effizienz,% |
|
| VSWR |
|
| Stromnetz mit 50 Hz Frequenz |
|
| Lifetime, h |
|
| Tiefe von Mikrowellenenergie Eindringen in Gewebe, cm |
|
|
|
| Operating frequency, GHz |
|
| Output power (average), W |
|
| Anode voltage (peak), kV, no more than |
|
| Efficiency, % |
|
| VSWR |
|
| Mains supply with 50 Hz frequency |
|
| Lifetime, h |
|
| Depth of microwave energy penetration in tissues, cm |
|
| Name | M-104 |
| Type | continous working |
| Application field | apllication in medical equipment and industrial heating and drying |
| Envelope | metal-ceramic |
| Mass,kg | 3 |
| Cooling method | forced air |
| Frequency range | 1st 933,3/2nd 896,7 |
| Output power | 200W |
| Filament voltage,V | 7 |
| Filament current,A | 6,5 |
| Anode voltage,kV | 2,5 |
| External loading agreement coefficient | 1,1 |

Artikel 18 / 188